Question 

How do I data log using FlashScan V2?

Answer 

FlashScan V2

Follow these steps to log the selected controller.

  1. Setup FlashScan V2 for BBX features if not already setup, inlcuding selecting PIDs for logging.
  2. Connect your FlashScan V2 device to your vehicle.
  3. Turn the vehicle ignition On.
  4. Navigate to the F1 Scan Tool -> F1 Select PIDs menu option.
  5. Select correct controller type from BBX configured controllers.
  6. Navigate to the F1 Scan Tool -> F2 Data Logging menu option.
  7. Select F1: Record Data to commence the logging session.
  8. Start the vehicle and drive to record actual performance.
  9. Stop the vehicle and turn the ignition off prior to selecting Cancel on FlashScan V2 to save the log file.